Strange guiding with A-P 1200 GTO and PHD
      #3074905 - 04/29/09 12:43 PM Attachment (48 downloads)

Last week I was out doing some imaging and the guider was running fine, the graph function had the normal wave look to it in RA and Dec, this was when the scope was on the east side. Later on I did a flip and was imaging on the west side of the mount and noticed that the Dec axis was spiking in a very extreme, but uniform way. It was late and I decided to pack it in, I chalked it up to maybe a weak power pack.

I went out again the other night and was imagaing and guiding without problem on the east side of the mount. I did a flip, and again recalibrated PHD. Same thing when it was guiding, it was cycling north and south by a fair bit. Now it had my attention. I checked for loose bits on the mount and guider, all was well. I purposly changed my perfect balance to load against the Dec worm. Still no change. I then dug around in the keypad for the backlash settings and had '2' for the RA and '3' for Dec. I remember a long time ago setting these per the procedure in the AP manual. I increased the number for the Dec and the graph went really bad....so wrong way....tried level 2, 1, and 0. Now the mount is tracking properly, or so it seemed for the 10 mins I let it run.

It appears that the change I made corrected it, is someone able to help me understand what was going on, and what I did wrong? Attached is a pic of what the graph looked like before I changed the backlash numbers.

*edit* I'm using a SSAG and V1.9 of PHD

Edited by PGW Steve (04/29/09 12:54 PM)


Post Extras: Print Post   Remind Me!   Notify Moderator  
LLEEGE
True Blue
*****

Reged: 03/03/05

Loc: Cloud-chester,NY
Re: Strange guiding with A-P 1200 GTO and PHD new [Re: PGW Steve]
      #3075145 - 04/29/09 02:23 PM

The backlash on the AP's should be set at zero. Anything else would mean an adjustment was needed.

Post Extras: Print Post   Remind Me!   Notify Moderator  
nik hodges
scholastic sledgehammer


Reged: 04/20/07

Loc: UK
Re: Strange guiding with A-P 1200 GTO and PHD new [Re: LLEEGE]
      #3075307 - 04/29/09 03:41 PM

agreed, there are a number of threads on the AP yahoo tech group that discuss the same thing and this is what Roland and others recommend

Post Extras: Print Post   Remind Me!   Notify Moderator  
Aquatone
sage


Reged: 03/23/06

Loc: Moraga, CA (Bay Area)
Re: Strange guiding with A-P 1200 GTO and PHD new [Re: nik hodges]
      #3077929 - 04/30/09 09:31 PM

Yes I have experienced exactly the same thing with my AP1200. Set the backlash to zero.

Chris


Post Extras: Print Post   Remind Me!   Notify Moderator  
PGW Steve
Pooh-Bah


Reged: 10/03/06

Loc: Winnipeg, Canada
Re: Strange guiding with A-P 1200 GTO and PHD new [Re: Aquatone]
      #3078146 - 04/30/09 11:30 PM

Thanks for the tips, I can't wait to try it out again!!

Post Extras: Print Post   Remind Me!   Notify Moderator  
Pages: 1


Extra information
18 registered and 35 anonymous users are browsing this forum.

Moderator:  Bowmoreman, bilgebay, iceblaze 

Print Thread

Forum Permissions
      You cannot start new topics
      You cannot reply to topics
      HTML is disabled
      UBBCode is enabled


Thread views: 579

Jump to

CN Forums Home


Cloudy Nights LLC
Cloudy Nights Sponsor: Astronomics