      #3093236 - 05/08/09 07:15 PM

I have an astcg5 that is kind of flakey. I have set it up about 15 times. about half of that worked correctly. went goto, and tracked nicely. the other half is running me nuts! I bought it previously owned, so returning is not an option. It has the gps add-on component. at first I thought it was user error. I do not think so anymore. one problem I found and corrected was the drive gear was adjusted too far away from the dec axis, and it would not handle a heavy refractor. this has been corrected. now... well, sometimes when I go for an alignment star, it almost goes to it, then drifts away at about 5x, without ever stopping. last night it did this,and all I wanted to do was look at the moon and saturn with my binos. So I thought no problem, all I want is tracking , so I did quick-align. no go. moon kept drifting out like there was not any tracking at all. There has been a few times when I had no problem at all! has anyone ever had this situation ? If so, what is it and how do I cure it? Any suggestions?

Theo


Post Extras: Print Post   Remind Me!   Notify Moderator  
waassaabee
Post Laureate
*****

Reged: 11/26/07

Loc: Central California Coast
Re: Intermittent astcg5 new [Re: cavefrog]
      #3093251 - 05/08/09 07:21 PM

Try a factory reset. If you've had any flaky power it may have tweaked things.

Post Extras: Print Post   Remind Me!   Notify Moderator  
GaryML
sage
*****

Reged: 02/16/09

Loc: San Diego, California
Re: Intermittent astcg5 new [Re: cavefrog]
      #3093442 - 05/08/09 09:15 PM

My CG-5 ASGT was also acting flakey last night. Must have been the full moon.

In any event, I looked over the suggestions on the Celestron Web site this morning for a "run-away slewing" problem. They suggested checking your cable connections and your power connections, among other things. I did stumble over my power cord last night and may have partially dislodged it, and I think my battery may have some issues as well, so I will be trying it with the A/C adapter.

I recently added the GPS kit. I found that you need to wait and let the GPS sync and update the data in the hand controller before doing an alignment. I failed to to this once, and the alignment was way, way off because the date and time were from my previous session and were not updated. The second time I waited and saw the time and date update flash by on the hand controller, and then all was normal. It would have been nice if this was mentioned somewhere in the instructions.


Post Extras: Print Post   Remind Me!   Notify Moderator  
cavefrog
Carpal Tunnel
*****

Reged: 11/11/08

Loc: loozyanna
Re: Intermittent astcg5 new [Re: GaryML]
      #3093655 - 05/08/09 11:50 PM

Allright , well I had done a factory reset in the house. next time I took it out, it worked fine. then the next time I took it out got the results described above. I use a lawn tractor battery for power. maybe I'll try house current next time. on the third time i used it, I had found that one has to wait for the gps to sync, that was one of the reasons for thinking the problem was user error. as far as bad connections... I have had a few times that when I power it up, nothing happens, no writing in the panel, just background red. I unplug, then replug and it starts up as it is supposed to. I have read that the on/off switch is a common problem. when I bought the mount, I was told the switch was bad, so I never used it. I just plugged/unplugged as needed. possibly there is resitance in the switch?

Theo


Post Extras: Print Post   Remind Me!   Notify Moderator  
waassaabee
Post Laureate
*****

Reged: 11/26/07

Loc: Central California Coast
Re: Intermittent astcg5 new [Re: cavefrog]
      #3093687 - 05/09/09 12:11 AM

Check the contacts in the socket on the mount. Make sure they are making GOOD contact. With care you can adjust .

Post Extras: Print Post   Remind Me!   Notify Moderator  
cavefrog
Carpal Tunnel
*****

Reged: 11/11/08

Loc: loozyanna
Re: Intermittent astcg5 new [Re: waassaabee]
      #3094493 - 05/09/09 01:18 PM

of which socket do you refer? power or hbx? both?

Theo


Post Extras: Print Post   Remind Me!   Notify Moderator  
rmollise
Postmaster
*****

Reged: 07/06/07

Re: Intermittent astcg5 new [Re: cavefrog]
      #3094814 - 05/09/09 04:49 PM

Quote:

of which socket do you refer? power or hbx? both?

Theo




The place on the mount where you plug the power cord in. Spread the pins gently with a jeweler's screwdriver and your troubles will likely be over.



Edited by rmollise (05/09/09 05:01 PM)


Post Extras: Print Post   Remind Me!   Notify Moderator  
cavefrog
Carpal Tunnel
*****

Reged: 11/11/08

Loc: loozyanna
Re: Intermittent asgt-cg5 new [Re: rmollise]
      #3095154 - 05/09/09 09:13 PM

Ah! I should have thought of that ! I have read about that cure before. more than once! but I was not thinking about this being a power problem. ok, thanks. Im'a gonner try that next time. I'll post ....success or no. Thanks fer the brain jog!

Theo


Post Extras: Print Post   Remind Me!   Notify Moderator  
AlanT
professor emeritus
*****

Reged: 08/20/07

Loc: 122º36' W, 47º37' N, WA USA
Re: Intermittent asgt-cg5 new [Re: cavefrog]
      #3100562 - 05/12/09 02:47 PM

Another remote possibility:

My CG-5 had an intermittent power problem. It would turn on or off if I jiggled the jack where it plugs into the mount. Turned out that one of the legs on the power connector that solder to the circuit card was broken. Sometimes it would make and maintain contact, sometimes not.

Had to take the mount apart enough to get the card out and replace the connector. Since then it's been fine.

al


Post Extras: Print Post   Remind Me!   Notify Moderator  
Pedestal
Post Laureate
*****

Reged: 03/11/06

Loc: Smoggy Bottom, Baytown,Texas
Re: Intermittent asgt-cg5 new [Re: AlanT]
      #3101311 - 05/12/09 10:05 PM

Had this happen on an SLT. Drove me nuts until I finally found the cold solder joint.
Hubert


Post Extras: Print Post   Remind Me!   Notify Moderator  
Pages: 1


Extra information
17 registered and 28 anonymous users are browsing this forum.

Moderator:  Bowmoreman, bilgebay, iceblaze 

Print Thread

Forum Permissions
      You cannot start new topics
      You cannot reply to topics
      HTML is disabled
      UBBCode is enabled


Thread views: 359

Jump to

CN Forums Home


Cloudy Nights LLC
Cloudy Nights Sponsor: Astronomics