Return to the Cloudy Nights Telescope Reviews home pageAstronomics discounts for Cloudy Nights members
· Get a Cloudy Nights T-Shirt · Submit a Review / Article

Click here if you are having trouble logging into the forums

Privacy Policy | Please read our Terms of Service | Signup and Troubleshooting FAQ | Problems? PM a Red or a Green Gu… uh, User

Equipment Discussions >> Mounts

Pages: 1
Holydiver
newbie


Reged: 12/21/11

DEC is lagging on CG-4
      #5643654 - 01/26/13 12:51 AM

So I bought an Orion Mini 50mm so I can increase my exposure limit of 30 seconds with my CG-4 and I've noticed that my DEC lags a bit, I've ruled out my Synscan GOTO motor as the culprit.
If I move the DEC up, then go to move it down, it lags for about 5 seconds before it begins to go down, same if I move it down, it lags before it begins to go up.
The length of the lag correlates with the hand controller speed, so if I use move the DEC really fast speed it isn't noticeable, but if I try to move it at the tracking speed it takes about a minute to catch up.
So PHD can't calibrate DEC because it lags for about a minute before it actually begins to move.
Any ideas?

I suspect (but I may be wrong) that it is the connection between these two parts here:
http://imgur.com/WBtmbZX


Post Extras: Print Post   Remind Me!   Notify Moderator  
rmollise
Postmaster
*****

Reged: 07/06/07

Re: DEC is lagging on CG-4 new [Re: Holydiver]
      #5643950 - 01/26/13 08:31 AM

This is backlash. On these mounts you will pretty much have to live it it. It's generally not much of a problem if it's not too bad. Five seconds is a bit much, and it's possible you might be able to reduce it by tightening the gears a bit, but the usual solution is to increase the calibration steps in PHD. On ANY mount, this should be set to about 1500 - 2000 when using a 50mm guide scope. Good luck.

Post Extras: Print Post   Remind Me!   Notify Moderator  
Holydiver
newbie


Reged: 12/21/11

Re: DEC is lagging on CG-4 new [Re: rmollise]
      #5655407 - 02/01/13 12:57 AM

I've discovered that I can remove the minute+ DEC backlash I get by setting the backlash to 0°20'00 in my synscan hand controller.

Problem is, when the scope is connected to EQMOD and PHD, it disables the backlash settings in the hand controller.

There appear to be backlash settings in EQMOD but they don't seem to do much and they are in msec rather than degrees.

Is there any way I can translate the 0°20'00 DEC backlash settings on the hand controller into backlash settings that work in EQMOD and PHD?

If not, is there another 3rd party program that allows me to adjust for backlash?

Edited by Holydiver (02/01/13 12:58 AM)


Post Extras: Print Post   Remind Me!   Notify Moderator  
rmollise
Postmaster
*****

Reged: 07/06/07

Re: DEC is lagging on CG-4 new [Re: Holydiver]
      #5655900 - 02/01/13 09:28 AM

No. What you need to do is try setting the PHD Brain settings as I suggested. If that won't allow you to calibrate, the option is adjust the gears.

Post Extras: Print Post   Remind Me!   Notify Moderator  
Pages: 1


Extra information
7 registered and 32 anonymous users are browsing this forum.

Moderator:  Dave M, richard7, bilgebay, iceblaze 

Print Thread

Forum Permissions
      You cannot start new topics
      You cannot reply to topics
      HTML is disabled
      UBBCode is enabled


Thread views: 444

Jump to

CN Forums Home


Cloudy Nights LLC
Cloudy Nights Sponsor: Astronomics