Return to the Cloudy Nights Telescope Reviews home pageAstronomics discounts for Cloudy Nights members
Get a Cloudy Nights T-Shirt Submit a Review / Article

Click here if you are having trouble logging into the forums

Privacy Policy | Please read our Terms of Service | Signup and Troubleshooting FAQ | Problems? PM a Red or a Green GuÖ uh, User

Equipment Discussions >> Mounts

Pages: 1
pcaker
newbie


Reged: 03/26/13

Celestron CGEM - mechanical problems
      #5760561 - 03/27/13 03:01 PM

My CGEM mount is showing at least 2 and possibly 3 apparent quality control problems, which I describe below:

1. If the declination axis pointer is set to the initial basic position before starting alignment, so that the 2 pointers line up, the wedge mount above is rotated anti-clockwise at least 2 to 3 degrees from being parallel to the r.a. axis. Apparently, one or both of the pointers are seriously out of position. I have assumed that it is more important for the mount to be parallel than for the pointers to line up, so that is what I try to achieve.

2. If I line up the axes pointers, see above, then tighten the rotation lock bolt, the mount forcibly rotates another 1 to 2 degrees during the tightening. I am not strong enough to prevent this happening, and I am not weak. This, I suspect, is more of a design problem than quality control. The tightening bolt clamp design is just too crude, transmitting rotational force to the collar instead of solely radial clamping force. Therefore, I have to anticipate this tightening mount rotation and set the pointers initially out of alignment. In fact, I have to allow for the problem described in (I.) above, plus the tightening forced offset rotation of problem (2.).

Therefore, if it really is critical to get the wedge mount initially perfectly parallel to the r.a. axis, Celestron sure donít make it easy.

3. The manual altitude adjustment bolt is unable to increase the mountís altitude by itself, and requires major additional force applied to the mount to move it (the opposite bolt is of course backed off). The altitude bearing is just too tight. This does not matter too much when setting the location latitude, as at the time the mount is not set up precisely and the jerking around of the whole mount and tripod does not matter too much. However, for polar alignment, where precise careful manual adjustment of the altitude is required without disturbing other alignments, it is a fatal problem.

In practice, after doing a 2 star alignment plus 4 calibration stars, the goto accuracy is good to very good, and for visual use more than adequate.

For astrophotography, I have found the drift method of polar alignment to be too time consuming - on top of the time for basic calibration, plus the time consuming effects of the problems described above, and I am going to try the iterative method. However, neither method is possible if I cannot solve problem (3).

Any comments, insights or advice would be appreciated.

Edited by pcaker (03/27/13 08:46 PM)


Post Extras: Print Post   Remind Me!   Notify Moderator  
rmollise
Postmaster
*****

Reged: 07/06/07

Re: Celestron CGEM - mechanical problems new [Re: pcaker]
      #5760626 - 03/27/13 03:36 PM

1. The important thing is that you start from the same position each time.

2. See above.

3. There is no declination bolt. There is an altitude bolt and an azimuth bolt. Do you mean right/left or up/down? If the latter, make sure the bolt that holds the head to the tripod is not too tight until you are polar aligned. If the former, do the adjustment before you put scope/weights on mount.

If you don't want to drift, why aren't you using the AllStar polar alignment?


Post Extras: Print Post   Remind Me!   Notify Moderator  
Nitpick
member


Reged: 02/11/13

Re: Celestron CGEM - mechanical problems new [Re: rmollise]
      #5761269 - 03/27/13 08:44 PM

I don't know about the other points but re: #1, when the declination pointers are lined up on my CGEM, the clamp head is rotated about five degrees counter-clockwise (when looking north) from vertical. I didn't (and don't) think that's an issue.

But I could be wrong.


Post Extras: Print Post   Remind Me!   Notify Moderator  
pcaker
newbie


Reged: 03/26/13

Re: Celestron CGEM - mechanical problems new [Re: rmollise]
      #5761322 - 03/27/13 09:10 PM

Thanks for your comments.
I mean the up & down or altitude movement which I thought I had clarified by my reference to setting the location latitude with it. However, I have edited my text to refer to altitude instead.
I had thought the All-Star polar alignment was a drift method, but yes I should be trying it out preferentially. After the All-Star polar alignment, the undoing of the previous alignment, and re-doing it, without losing your place on the menu, is something that has not gone well for me.
The stiff altitude bearing seems to me to remain as a problem for the All-Star method.


Post Extras: Print Post   Remind Me!   Notify Moderator  
Stew57
Carpal Tunnel
*****

Reged: 05/03/09

Loc: Silsbee Texas
Re: Celestron CGEM - mechanical problems new [Re: pcaker]
      #5761383 - 03/27/13 09:48 PM

Rod is right make sure that the front bolt is completely loose. It is a only a stop, so when you finish aligning just snug it up. If set correctly you can raise the mount head via the shaft some. The CW keep the mount in contact with the front stop bolt. If it is still tight something is wrong, bad threads maybe?

Post Extras: Print Post   Remind Me!   Notify Moderator  
Pages: 1


Extra information
18 registered and 29 anonymous users are browsing this forum.

Moderator:  Dave M, richard7, bilgebay 

Print Thread

Forum Permissions
      You cannot start new topics
      You cannot reply to topics
      HTML is disabled
      UBBCode is enabled


Thread views: 356

Jump to

CN Forums Home


Cloudy Nights LLC
Cloudy Nights Sponsor: Astronomics