Equipment Discussions >> Reflectors

Pages: 1 | 2 | 3 | (show all)
Peter10
member


Reged: 03/31/07

Collimation and Star Symmetry new
      #6224980 - 11/30/13 11:25 AM Attachment (64 downloads)

This is crop of the central area of my monochrome QHY9 CCD camera (M33). The image is an LRGB composite of several 10 minute subs aligned and stacked in MaximDl ver. 5.24. Though the star elongation "appears" to be tracking related - it is actually an intrinsic feature of the telescope. The exact same elongation is present using very short exposures on the order of several seconds.

The full image when presented at a 50% reduction actually looks quite good - but there is an underlying problem here that needs to be resolved. The scope was collimated using a set of Catseye Tools at f/5 prior to inserting my ASA 0.73X focal reducer.

Images recorded with the ASA corrector installed and the default alignment (generated by the Catseye Tools) show oblate stars. The image posted here was "improved" by making small corrections at the PM to improve star symmetry. As you can see, the final result is marginal at best. With additional effort I am sure it could be further improved.

I felt justified adjusting the PM alignment since it is at least possible that the corrector introduced some tilt that was not present during the original collimation performed without it. Is this a reasonable way to proceed? Also, is there a systematic way to impart PM adjustments with the only feedback being the star field displayed on the monitor? With three adjusters on the PM and two directions (CW and CCW) it is easy to walk way off when trying to improve things.


Peter

Edited by Peter10 (11/30/13 11:43 AM)


Post Extras: Print Post   Remind Me!   Notify Moderator  
GlennLeDrew
Postmaster
*****

Reged: 06/18/08

Loc: Ottawa, Ontario, Canada
Re: Collimation and Star Symmetry new [Re: Peter10]
      #6225029 - 11/30/13 11:50 AM

I would look for symmetry of star shape and size near the four corners, at the same relative position with respect to the frame. There is software which can do this analysis, indicating field tilt.

If the elongation shown here is indeed representative of what the *optics* are producing, that is quite bad.

Is there a way to differentially rotate the reducer? This should reveal if it has tilt, wedge, or some other problem.

Are you certain you have no sag at the attachments?

And in general, I feel final collimation should be performed in the as-used configuration.


Post Extras: Print Post   Remind Me!   Notify Moderator  
orlyandico
Post Laureate
*****

Reged: 08/10/09

Loc: Singapore
Re: Collimation and Star Symmetry new [Re: GlennLeDrew]
      #6225243 - 11/30/13 01:48 PM

I have a similar issue.. I am using an AT8IN also with the Keller reducer. These are the corners of my ST8300M, 5-minute guided exposure. There is obvious elongation even on 10-second exposures however. I thought it was tilt, but tugging on the focuser while watching the "live view" did not change the shape of the stars, it just moved them around.









Post Extras: Print Post   Remind Me!   Notify Moderator  
orlyandico
Post Laureate
*****

Reged: 08/10/09

Loc: Singapore
Re: Collimation and Star Symmetry new [Re: orlyandico]
      #6225402 - 11/30/13 03:21 PM

Peter10, I rechecked and my spacing was 66.5mm.

Found some poster somewhere on the ap-ug mailing list who said that the spacing should not exceed 65mm, but as low as 63mm can be tolerated.

I've adjusted my Baader VariLock to give 65mm, will see how that goes..


Post Extras: Print Post   Remind Me!   Notify Moderator  
Peter10
member


Reged: 03/31/07

Re: Collimation and Star Symmetry new [Re: orlyandico]
      #6225640 - 11/30/13 05:58 PM

Hi orlyandico:

Good luck with the revised spacing between the corrector and the focal plane. I have experimented with this as well - though I have not found that it improved the on axis performance of the telescope/corrector system. I actually had the corrector re-aligned (at the manufacturer) thinking it had a tilted or otherwise misaligned component. This did not provide any improvement in imaging performance.

Generally, I consider myself to be good at collimation. I never seem to have these problems when using the scope visually, but imaging in another story. I am beginning to suspect that the wall thickness (0.030") of my steel tubed Newt is insufficient to hold collimation. The problem with this reasoning is that I can NEVER get acceptable stars even when I attempt to optimize collimation for a given target.

I get good agreement between the Catseye tools and my laser collimator. The problem is that this never translates into properly formed stars. To be brutally honest, the on axis performance even with the reducer removed is not "perfect".

With the rare exception of a few "gifted imagers", I usually see this same problem to varying degrees on most Newtonian images. I do not plan to give up, since I really like the attributes of Newts. I just hope I can achieve this goal in one human lifetime.

Peter


Post Extras: Print Post   Remind Me!   Notify Moderator  
Peter10
member


Reged: 03/31/07

Re: Collimation and Star Symmetry new [Re: GlennLeDrew]
      #6226126 - 11/30/13 11:06 PM Attachment (18 downloads)

Hi Glenn:

Here are small crops from the corners of an image taken with the scope ans ASA corrector. The sensor has an APSC form factor so the edges may be at the limit of the corrected zone for the 2" ASA corrector. Next time out I try rotating the camera/corrector. Using CCD Inspector, the total tilt comes in at 12% for this image. It shows collimation good to 7 arc-sec.

Peter


Post Extras: Print Post   Remind Me!   Notify Moderator  
orlyandico
Post Laureate
*****

Reged: 08/10/09

Loc: Singapore
Re: Collimation and Star Symmetry new [Re: Peter10]
      #6226324 - 12/01/13 02:20 AM

Peter, I am glad to know that the Catseye agrees well with the laser colli, because I'm not in the mood to buy a Catseye.

I have seen some pretty good Newt images though with the Baader or Paracorr. Maybe there's something about the Keller that you and i don't know?

This is what I did to my steel-tube newt:



I think it can hold collimation well enough, because when I pull/tug on the focuser while watching the CCD live view, the stars return to their normal locations.

One other thing we can try - if you can find a local sheet metal shop, ask them to roll a piece of maybe 1mm or 2mm steel plate to the ID of your tube, then put that plate inside. This is going to be my next move. Then put a few holes in the existing tube to attach the inner steel plate.

That, and get a Feathertouch focuser. I'm still using the stock CPC linear bearing crayford.

That said you are right.. even on-axis my stars aren't round (with the corrector in place). I should try rotating it and see if the "tails" on the stars change direction.

I've been using the AT8IN + Keller though, here are a few photos..





One can see the non-round stars even at these reduced image sizes.

(and no, these are not tracking errors.. a Mach1 at 600mm focal length does not have tracking errors)


Post Extras: Print Post   Remind Me!   Notify Moderator  
Howie Glatter
Vendor


Reged: 07/04/06

Re: Collimation and Star Symmetry new [Re: orlyandico]
      #6226572 - 12/01/13 09:24 AM

"I should try rotating it and see if the "tails" on the stars change direction."

That's a very good idea. I think it would definitively confirm or exclude out-of-square elements of the corrector optics.


Post Extras: Print Post   Remind Me!   Notify Moderator  
orlyandico
Post Laureate
*****

Reged: 08/10/09

Loc: Singapore
Re: Collimation and Star Symmetry new [Re: Howie Glatter]
      #6226895 - 12/01/13 12:08 PM

Peter, what sort of focuser are you using?

Post Extras: Print Post   Remind Me!   Notify Moderator  
Peter10
member


Reged: 03/31/07

Re: Collimation and Star Symmetry new [Re: orlyandico]
      #6227012 - 12/01/13 12:56 PM

I am using a very good 2" Moonlite focuser. This unit seems to be stable and well made so I do not consider it to be a likely candidate. I plan to try rotating the camera/corrector when the clouds roll away.

I purchased an aluminum tube from the Hastings company to replace my current thin-walled steel tube. The new tube has a wall thickness of 0.094" and is significantly stiffer than the OEM tube. Apparently we have been thinking along the same lines - specifically that the tube stiffness needs to be improved.

It is curious that Jason is working with similar hardware and does not experience the same problems. On the other hand, he is not operating with the ASA corrector in the mix.

It is my opinion that the corrector is not the only problem. If I remove the corrector and critically examine the on-axis performance of my telescope it still does not fully meet expectations. Obviously, as you extend to the edges of the field, coma really degrades star shape.

I should point out that all of our collimation work occurs with a light weight laser or collimation tool in the focuser. When imaging, we transition to a (at least in my case) from a single "tool" to a camera, filter wheel and corrector. Additionally, this stack is long so it potentially couples in some undesired moments into the telescope tube/focuser. I suspect that we are not ever operating with the alignment we originally established.

The added weight would tend to de-collimate at the focuser end of the telescope not at the PM end. My efforts to improve the imaging performance at the "system level" have been limited to adjustments made with the PM. It seems that the offending component may actually be the secondary mirror. Angular errors at the secondary can not be mitigated using angular corrections imparted with the PM.

Now the question is, is there a way to meaningfully "tune" the angular position of the secondary mirror with all of the imaging hardware in place? Based on my experience, this will be difficult since the control over SM angular position is very coarse. I would bet that playing with this adjustment without feedback from a "tool" is walking further into the quick sand. On the other hand, we may already be in the quick sand!

Peter


Post Extras: Print Post   Remind Me!   Notify Moderator  
GlennLeDrew
Postmaster
*****

Reged: 06/18/08

Loc: Ottawa, Ontario, Canada
Re: Collimation and Star Symmetry new [Re: Peter10]
      #6227071 - 12/01/13 01:25 PM

How about attaching/detaching a similar arrangement of weight/moment to the rig while collimating?

Post Extras: Print Post   Remind Me!   Notify Moderator  
orlyandico
Post Laureate
*****

Reged: 08/10/09

Loc: Singapore
Re: Collimation and Star Symmetry new [Re: GlennLeDrew]
      #6227089 - 12/01/13 01:35 PM

Actually I collimate with the focuser facing down. But even when imaging something close to zero declination (which leaves the focuser still pointing down) I still get those funny star shapes...

I do notice that the star moves a bit when I lock down the focuser. I suspect that the locking screw is tilting the entire focuser drawtube. Maybe it's time for a Feather touch...


Post Extras: Print Post   Remind Me!   Notify Moderator  
Peter10
member


Reged: 03/31/07

Re: Collimation and Star Symmetry new [Re: Peter10]
      #6227104 - 12/01/13 01:40 PM Attachment (19 downloads)

Here is a central crop from a recent image. I adjusted the PM tip/tilt to improve star shape AFTER setting collimation using tools. Without this post collimation tweaking, the star shape was worse. This still is not what I would hope for.

Peter


Post Extras: Print Post   Remind Me!   Notify Moderator  
orlyandico
Post Laureate
*****

Reged: 08/10/09

Loc: Singapore
Re: Collimation and Star Symmetry new [Re: Peter10]
      #6227191 - 12/01/13 02:10 PM

That is significantly better than what I'm getting at the center of my images.. did you tweak the primary collimation with the reducer/camera in place? can you share your procedure?

What I've seen is that when I move the primary the stars move around but their shape doesn't change.

Here's an issue I found (just recorded it)

http://www.youtube.com/watch?v=I9BPqL8QZNg

if i wiggle the focuser around, the shadow of the primary center donut doesn't move (obviously, this is the virtue of the barlowed laser) but it's obvious that collimation is affected by the focuser wiggling around.


Post Extras: Print Post   Remind Me!   Notify Moderator  
Peter10
member


Reged: 03/31/07

Re: Collimation and Star Symmetry new [Re: orlyandico]
      #6227352 - 12/01/13 03:43 PM

I performed a standard alignment using the Catseye tools (including the autocollimator). Next, I used very short exposures to observe the shape of a star that was placed at the center of the cf the camera's field of view (ASA corrector installed). I make adjustments to the tip/tilt of the PM, recenter and then re-imaged the star. I find it useful to identify and write down the action and sense of each of the three PM collimation screws. This will provide a road map for selecting the appropriate collimation screw as you proceed. You will probably conclude that this is more of an art than science but, it eventually comes together.

Though this process helps, it does not rapidly and efficiently converge on a final alignment solution. You are essentially chasing your tail trying to improve things. I think the weight of the camera and other accessories compromise the collimation making this step necessary. My question remains, should the adjustments be made at the secondary mirror since this is probably the source of the "alleged" mis-collimation.

Peter


Post Extras: Print Post   Remind Me!   Notify Moderator  
Peter10
member


Reged: 03/31/07

Re: Collimation and Star Symmetry new [Re: GlennLeDrew]
      #6227687 - 12/01/13 06:32 PM

Hi Glenn:

Good suggestion. I will try this out ASAP.

Peter


Post Extras: Print Post   Remind Me!   Notify Moderator  
orlyandico
Post Laureate
*****

Reged: 08/10/09

Loc: Singapore
Re: Collimation and Star Symmetry [Re: Peter10]
      #6228254 - 12/02/13 12:45 AM

I have tried a variation of your approach, Peter - adjust primary while watching the CCD. This has proven not useful, as the star shapes do not change appreciably. I do not make gross changes to the primary collimation (it stands to reason that only very small changes are necessary, since rough collimation was already done with the laser).

Post Extras: Print Post   Remind Me!   Notify Moderator  
Peter10
member


Reged: 03/31/07

Re: Collimation and Star Symmetry new [Re: orlyandico]
      #6230091 - 12/02/13 07:54 PM

Actually I had to move my PM significantly to improve the star symmetry. From my perspective, it is not hard to believe that hanging several pounds of hardware off of the focuser can introduce large collimation errors. Even though you reinforced the telescope tube around the focuser, I am not sure if this is sufficient.

The true check would be to collimate the scope as usual and then verify collimation with a weight added to the focuser(as Glenn suggested). The weight obviously should approximate the weight of the imaging hardware you use. You can try this using your laser.

Peter

Edited by Peter10 (12/02/13 08:26 PM)


Post Extras: Print Post   Remind Me!   Notify Moderator  
Peter10
member


Reged: 03/31/07

Re: Collimation and Star Symmetry new [Re: Peter10]
      #6230348 - 12/02/13 09:47 PM

Here is a video (from the web) showing the focuser sag issue. I believe that this is the source of my problem.

http://www.youtube.com/watch?feature=player_embedded&v=TTGCutUicp4

Peter


Post Extras: Print Post   Remind Me!   Notify Moderator  
orlyandico
Post Laureate
*****

Reged: 08/10/09

Loc: Singapore
Re: Collimation and Star Symmetry new [Re: Peter10]
      #6230511 - 12/02/13 11:03 PM

Peter, I've seen that issue. That's why I added the reinforcing plate under the focuser. I emailed the guy who posted that image, he also put a plate under his focuser..

Post Extras: Print Post   Remind Me!   Notify Moderator  
Pages: 1 | 2 | 3 | (show all)


Extra information
12 registered and 23 anonymous users are browsing this forum.

Moderator:  ausastronomer, Phillip Creed, JayinUT, okieav8r 

Print Thread

Forum Permissions
      You cannot start new topics
      You cannot reply to topics
      HTML is disabled
      UBBCode is enabled


Thread views: 1664

Jump to

CN Forums Home


Cloudy Nights LLC
Cloudy Nights Sponsor: Astronomics